Drivers Siemens Network & Wireless Cards

  

Details

  1. Drivers Siemens Network & Wireless Cards Compatible
  2. Drivers Siemens Network & Wireless Cards Customer Service

Download drivers for network card for Siemens SIMATIC Field PG M4 laptop Windows 10 x64, or download DriverPack Solution software for driver update. The SIMATIC Field PG M6 is based on the latest Intel Coffee Lake processor. The Siemens S5 driver works in conjunction with KEPServerEX to exchange data between OPC clients and Siemens S5 PLCs using the AS511 protocol, which allows a direct connection to the programming port of the PLC. © 2001-2021 Softpedia.All rights reserved. Softpedia® and the Softpedia® logo are registered trademarks of SoftNews NET SRL Contact. Privacy Policy. Cookie. Home NETWORK SIEMENS GIGASET USB ADAPTER 108 gigaset usb adapter 108 Driver Download. You can find the driver files from below list: File Name: Size: usb. Updating device drivers Gigaset USB Adapter 108 Gigaset USB Adapter 108 and another wireless Gigaset Communications GmbH is a trademark licensee of Siemens. After installing the drivers for the network card, you must install the TCP/IP protocol driver. In the Control Panel folder, start the Network program. The network dialog contains the Configuration register; click on the Add button here. In the Choose Network Component Type list box, choose the Protocol line and then click on Add.

Caution
Precautions for adding a new driver onto Windows Vista or later
Precautions for adding a new driver at Daylight Saving Time
TitleSiemens AG TIA Portal Ethernet Driver
VersionVer. 1.15.09
Supported SoftwareThe required versions of software for this driver installer are as follows.
ModelRequired driver version
GP4100 Series (GP-4114T)
GP4000 Series
GP4000H Series
SP5000 Series (SP-5B10)
GP-Pro EX
Ver. 4.06.300 or later
Pro-Server EX
Ver. 1.31.000 or later
SP5000 Series (SP-5B00, SP-5B90)GP-Pro EX
Ver. 4.08.200 or later
Pro-Server EX
Ver. 1.37.000 or later
SP5000 Series (SP-5B41, SP-5B40)
IPC Series for WinGP
General PCs for WinGP
GP-Pro EX
Ver. 4.05.100 or later
Pro-Server EX
Ver. 1.31.000 or later
You can check your version by 'Help' function → 'Version Info'.
Supported Devices
  • S7-1200 Series
  • S7-1500 Series
Supported UnitsRequired versions depend on models.
Please check 'Supported Models / Version' or the required versions of GP-Pro EX.
Required driver versions for different models are listed below
ModelRequired driver version
GP4100 Series (GP-4114T)Ver. 1.11.01 or later
GP4000 SeriesVer. 1.11.01 or later
GP4000H SeriesVer. 1.11.01 or later
SP5000 Series (SP-5B10)Ver. 1.11.01 or later
SP5000 Series (SP-5B00, SP-5B90)Ver. 1.11.01 or later
SP5000 Series (SP-5B41, SP-5B40)Ver. 1.10.00 or later
IPC Series for WinGPVer. 1.10.00 or later
General PCs for WinGPVer. 1.10.00 or later
Device/PLC
Connection Manual
For details, please read the 'Device/PLC Connection Manual' in the lower part of this page.
For general information regarding Device connection and documentation conventions, please refer to 'Device/PLC Connection Manual'.
Updated ContentsVer. 1.15.09 The following feature was supported.
  • TIA Portal V16
  • Communication with latest firmware version of each PLC.
NotesWhen using GP-Pro EX before Ver. 4.06.000. Please make sure to transfer a GP-Pro EX project by 'All transfer project' every time tag import has been executed.
LimitationsDepending on the data size of imported TIA Portal project, transferring GP-Pro EX project data may be failed. Even if transferring is completed, an error message may be displayed when the display starts up. In that case, please delete unused tags from the TIA Portal project you will import. After that, please try to re-import.

How to install (This is a self-extracting file.)

Network

Prior to installation, be sure to close all software applications that are running.

Drivers siemens network & wireless cards online
  1. Click on the above file name to download the data to desired folder.
  2. After the download to your PC is finished, double-click on the file’s icon to start the installer program.
  3. After the installer starts, follow the instructions given on each screen.
  4. After installation, execute GP-Pro EX.
  5. Select [Siemens AG] for 'Manufacturer' and [TIA Portal Ethernet] for 'Series' in [Device/PLC] settings of [System Settings] on the [Project] menu.
When using the driver, be sure to refer to the Device Connection Manual PDF (Shown above). Also, for general information regarding Device connection and documentation conventions please refer to 'Device/PLC Connection Manual'.

Terms of use / Cautions

Please acknowledge the following terms of use before you use our download service.
Download of any file signifies your agreement to the terms of use.
Terms and conditions

Download file

Installer :
32.46 MB (34,040,680Byte)
Wireless

Drivers Siemens Network & Wireless Cards Compatible

Device/PLC Connection Manual :
347.92 KB (356,274Byte)
Wireless
Device/PLC Reference Manual :
Drivers Siemens Network & Wireless Cards
328.26 KB (336,139Byte)

Update history

  • Ver. 1.15.09 The following feature was supported.
    • TIA Portal V16
    • Communication with latest firmware version of each PLC.
  • Ver 1.14.09 The following feature was supported.
    • There was problem of force termination in GP-Pro EX, when import it if TIA portal project has FB instance into the FB instance member.
  • Ver 1.14.08 The following feature was supported.
    • The mode is changed to overwrite from skip if tags already registered when import.
    The following issue was fixed.
    • An unknown address error was displayed if set multiple nodes on Ver.1.14.07.
  • Ver 1.14.07 The following feature was supported.
    • Reduce memory usage by import with filtering necessary tag information.
    The following issue was fixed.
    • By supported to TIA Portal V15.1, some projects become impossible import.
  • Ver 1.14.06 The following feature was supported.
    • Support the function block (FB) as data type.
  • Ver 1.14.05 The following feature was supported.
    • TIA portal V15.1
    • Import project with including group
    The following issue was fixed.
    • The import process was canceled in V1.13.02 or later, In the case importing a project with including data type 'Timer', if the selected PLC does not support this data type.
  • Ver 1.13.04 The following issue was fixed.
    • In the Individual Device Settings dialog box, using [Edit] to import tags sometimes caused variables used by parts on the screen to become 'Undefined'.
  • Ver 1.13.03 The following feature was supported.
    • The indicator for limitation size of TIA portal project was added on Individual Device Setting.
  • Ver 1.13.02 The following feature was supported.
    • TIA Portal V15
    The following issue was fixed.
    • Some TIA Portal projects cannot be opened when importing the TIA Portal project.
  • Ver 1.12.02 (Included in GP-Pro EX Ver. 4.07.300) The following feature was supported.
    • TIA Portal V14
  • Ver 1.11.01 (Included in GP-Pro EX Ver. 4.07.000) The following issues were fixed.
    • Importing the unnamed structure was failed.
    • Some TIA Portal projects cannot be opened when importing the TIA Portal project.
  • Ver 1.11.01 The following models were supported.
    • GP4100 Series (GP4114)
    • GP4000 Series
    • GP4000H Series
    • SP5000 Series (SP5B10)
    The following issue is fixed:
    • Grouped Data blocks and PLC tags cannot be imported.
  • Ver 1.10.00 New

Interface Description

IGSS offers an interface for connecting IGSS to Simatic S7/400, Simatic S7/300 and S7/200 using TCP/IP network.
The driver uses S7 functions for exchanging data between IGSS and Simatic S7 Series PLCs. The driver can only be used on network which allows TCP/IP traffic through port 102 (check your firewall settings).
The Simatic PLCs must be equipped with an Ethernet interface port or Ethernet CP board. Applicable CP boards are e.g. CP443-1 or CP443-1 IT for the S7/400 and CP343-1 for the S7/300. The PC must have an standard ethernet NIC installed.
The IGSS32 system polls the PLC equipment cyclically according to one of four user-defined time intervals. The time intervals are configurable from 100 milliseconds to 999 seconds. The system automatically groups process data in data blocks – thus fully exploiting the the communication link in relation to the present configuration.

Technical Data

Drivers Siemens Network & Wireless Cards Customer Service

Electrical Interface:IEEE Ethernet
Protocol:TCP/IP
Types of data:String, Fixed Point 8, 16, 28, 32, BCD 16, 32, Float 32, Timer, Counter, etc.
PLC types supported:S7/200, S7/300 and S7/400 directly on CPU port.
S7/200 equipped with CP243-1 or compatible.
S7/300 equipped with CP343-5, CP343-1 or compatible.
S7/400 equipped with CP443-5, CP443-1, CP443-1 IT or compatible.
Addressing:Node (PLC), Data type, index, bit offset. Simatic S7 Mnemonics are displayed.
Supported platforms:Windows Vista, Windows XP, Windows 2003 Server, Windows 2000
Max. telegram size:240 bytes pr. Telegram
Transmission speed:10 Mb/sec, 100 Mb/sec
Throughput:Up til 15 telegrams pr. Channel pr. Second (depending on available bandwidth).
Max. number of channels:32 channels
Max. number of nodes:255 nodes
PC hardware requirements:Standard NIC (Network interface board)
PC software requirements:Standard Microsoft Windows Protocol stack