  • (port 80) capability supporting up to 8 sensing heads Connection: M12 or RJ45 electrically isolated An opened Ethernet port will be closed automatically by the MI3 communication box if there is no data traffic within the time given by the command! 16.1 Wiring 16.1.1 Comm Box (metal) The connector on the box side is an M12 plug-in.
  • The 6.5-inch downward-firing driver and professionally-tuned slot port cabinet delivers floor-shaking bass worthy of a movie theater. Wireless Control Compatible with most Bluetooth® wireless-enabled devices, use your mobile phone, computer, or wireless audio device to stream whatever your mood requires.
Drivers raytek rsb port devices inc

Serial Port Monitor displays, logs and analyzes RS232/422/485 COM port activity. Intercept COM port activity with Serial Monitor by Eltima.

Drivers Raytek Rsb Port Devices

Evoluent Mouse Manager is an optional but powerful software that may be installed to configure the buttons to perform many common functions. For example, button 2 may be configured to perform a double click with a single actual click to open a program, button 3 may be configured to open a link in a new tab, button 4 may be configured to cycle through open tabs, button 5 may be configured to close a tab, etc. This reduces the need to frequently move your hand between the mouse and the keyboard, and the need to move the mouse and click different areas of the screen.

Install instructions:

1. Connect the VerticalMouse to a USB port and wait for Windows to set it up for basic functionality.

2. Remove any existing Evoluent driver or other mouse drivers, except for touchpad driver. Go to Programs and Features (Win 7) or Add or Remove Programs (XP) in Control Panel to find the drivers, or use the uninstaller below.

3. Click the link below to download and install the driver. After install is finished, click E icon on the taskbar to open Evoluent Mouse Manager for configuring the buttons.

4. Go to Control Panel, Mouse to uncheck the box for Enhance Pointer Precision and set the pointer speed slider to the middle for optimal control.

5. Press the pointer speed button on the mouse to set the hardware pointer speed to the MD (medium) setting.

v6.0.9.2 for Windows 7, 8 and 10

v6.0.3.0 for Windows 7, 8 and 10

Win 7: Go to Control Panel, Programs and Features, click Evoluent Mouse Manager, and click Uninstall.

Win 10: Start menu, Settings, System, Apps & Features, click on Evoluent Mouse Manager, and click Uninstall.

After install, button functions show as “Disabled”.

Solution: go to Control Panel, Programs and Features, uninstall Evoluent Mouse Manager. Download and install Mouse Manager again.

Evoluent Mouse Manager is an optional but powerful software that may be installed to configure the buttons to perform many common functions. For example, button 2 may be configured to perform a double click with a single actual click to open a program, button 3 may be configured to open a link in a new tab, button 4 may be configured to cycle through open tabs, button 5 may be configured to close a tab, etc. This reduces the need to frequently move your hand between the mouse and the keyboard, and the need to move the mouse and click different areas of the screen.

Before installing the Evoluent driver, go to Applications to find and uninstall any existing mouse or keyboard driver to avoid possible software conflicts.

Download and save the dmg file to the hard drive. Click on the dmg file to generate a pkg file. Click on the pkg file to install. You may have to temporarily allow installing programs downloaded from anywhere in System Preferences, Security and Privacy.

Note for users of High Sierra (10.13) and newer:

The Evoluent Mac driver (known as “extension” in Mac language) may be blocked in Mac OS 10.13 High Sierra by a new system security feature. Refer to this article on the Apple web site: https://developer.apple.com/library/content/technotes/tn2459/_index.html.

If the mouse buttons do not perform your selected functions in the driver, go to System Preference, Security to see if there is an option to allow the Evoluent extension. The option in the security system preference is only there for 30 minutes after the extension tries to load. If it is not there, restart the computer to reload it. The extension will be listed as software from Jack Lo (the creator). If after allowing the extension it is still not working, restart the computer again. If restarting does not work, uninstall and reinstall the Evoluent software and restart the computer.

To determine if Secure Kernel Extension Loading is blocking the Evoluent extension, go to Utilities and open the Console, select the system.log on the left, and search for ‘Evoluent’ to look for a line like this: EvoluentAgent[2218]: IORegistryEntrySetCFProperties Error! Result = 0x10000003.

If the system is blocking the extension, there will be a new line each time you try to change the settings.

Due to recent Mac OS update, our driver must be updated to maintain compatibility. We need a driver development kit from Apple but they have not replied to our request even after repeated emails. Therefore our driver development is unable to proceed. We apologize for the delay and will continue to contact Apple for the resource. Alternatively, the third party software USB Overdrive www.usboverdrive.com may be used to program the buttons on VerticalMouse. (Evoluent is not affiliated with USB Overdrive.)

Wired and USB wireless versions of the VerticalMouse 4 require no pairing. They are plug and play.The driver may be installed after they are plugged in.

Mac and Bluetooth versions of the VerticalMouse 4 require this pairing procedure before driver installation:

Go to System Preferences, Bluetooth and click Setup New Device or the plus sign + to add the mouse.Slide the On/Off switch on the Evoluent to the green position or cycle it off and on to begin pairing.

No other drivers are supplied, but the VerticalMouse works in most other operating systems with default system support.Shareware drivers for other Windows versions are at

(Evoluent has no business relationship with this vendor.)

For Evoluent VerticalMouse 4 only. VerticalMouse 3 wireless does not need this utility. Download and click to run. Follow the on-screen instructions. If the countdown timer does not begin after starting the utility and inserting the receiver, the receiver may be incompatible or defective.

Evoluent Receiver Pairing Utility v1.0 (for Windows only)

Essentials Keyboard pdf brochure

VerticalMouse 4 Right Wireless A4 size , letter size

VerticalMouse 4 pdf brochure

VerticalMouse 3 pdf brochure

Mouse-Friendly Keyboard letter size

  • 1Overview
  • 2Boards
  • 3How to config RS232 or RS485 mode

The Android/Linux UART/serial port access from user is through the tty-devices. The tty-devices have different names depending on UART driver on different board.

RS-485

RS-485 uses half-duplex communication, which means that one medium is shared for transmitting and receiving data.

Therefore the system needs to control the RS-485 transceiver's transmit mode.

Usually the UART RTS signal is used to switch the transmitter on and off.

RSB4710 Borad

Drivers Raytek Rsb Port DevicesDrivers Raytek Rsb Port Devices
COM NameDevice NodeRemark
COM0 /dev/ttyS0
pull to M2 interface for BT using
COM1
/dev/ttyS4
support RS232, no flow control
COM2
/dev/ttyS2
Debug Port
COM3
/dev/ttyUSB0
support RS232
COM4 /dev/ttyUSB1
support RS232
COM5
/dev/ttyUSB2 support RS232 and RS485
COM6
/dev/ttyUSB3
support RS232 and RS485





Note :

1. Only COM4、USB2COM0、USB2COM1、USB2COM2、USB2COM3 are designed for custom using.

2. Only USB2COM2 and USB2COM3 support RSB485.

3. COM2 is designed as debug port default.

Enter U-boot interrupt mode

Drivers Raytek Rsb Port Devices Gigabit

Connect device to debug port, and open debug console. See more : How_to_debug.

Press 'ctrl + c' key before power up the device, until get the following information on debug console :

Then you can input the following cammand to config UART mode.

Config Uart Mode

Only ttyUSB2 and ttyUSB3 support RS485 mode.

RS485 Mode:

RS232 Mode:


Note :

The default value is RS232.

Cp210x support four port, but RSB4710 Only ttyUSB2 and ttyUSB3 support RS485 mode.

Above command 'setenv uart_mode 0x0c', 0x0c means set bit2(ttyUSB2) and bit3(ttyUSB3) to 1 (0 means to RS232; 1 means to RS485).

Drivers Raytek Rsb Port Devices Inc

If you just want ttyUSB2 (or ttyUSB3)to be RSB485 mode, please change 0x0c to 0x04 (or 0x08).

Drivers Raytek Rsb Port Devices Download

Retrieved from 'http://ess-wiki.advantech.com.tw/wiki/index.php?title=How_to_use_UART_for_RK3399_RSB4710&oldid=19062'